Sign In | Join Free | My himfr.com
Home > Portable Reference Standard >

Portable Three Phase Meter Calibrator for Accurate Voltage and Current Measurement

Guangzhou GENY Electric Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Portable Three Phase Meter Calibrator for Accurate Voltage and Current Measurement from wholesalers
     
    Buy cheap Portable Three Phase Meter Calibrator for Accurate Voltage and Current Measurement from wholesalers
    • Buy cheap Portable Three Phase Meter Calibrator for Accurate Voltage and Current Measurement from wholesalers
    • Buy cheap Portable Three Phase Meter Calibrator for Accurate Voltage and Current Measurement from wholesalers

    Portable Three Phase Meter Calibrator for Accurate Voltage and Current Measurement

    Ask Lasest Price
    Brand Name : GENY
    Model Number : YC98S1
    Certification : ISO, CE
    Price : negotiate rates
    Payment Terms : T/T,L/C,D/P,T/T
    Supply Ability : 50 pcs/ 1 months
    Delivery Time : 6~8weeks
    • Product Details
    • Company Profile

    Portable Three Phase Meter Calibrator for Accurate Voltage and Current Measurement

    Portable Three Phase Meter Calibrator for Accurate Voltage and Current Measurement

    YC98S1 Portable 3 Phase Standard Meter


    The instrument YC98S1 is used to calibrate three phase, single phase, active or reactive energy
    meter who comply with GB/T17215.211 (IEC62052-11), GB/T17215.311 /321/322/323
    (IEC62053-11/21/22/23), and also it can be used as voltage, current and power meter to measure
    AC parameter of three phase power grid.

    This portable three phase standard meter comply to GB/T11150-2001 (IEC60736:2001),
    GB/T4793.2-2008 (IEC61010-1:2001).

    Test functions


    1. Can test one meter or two meters at the same time.
    2. Automatic test sequence using the scanning head for electronic and electromechanical meters
    3. Can synchronously calculate all data and display on the interface include full wave
    4. Can test active and reactive energy accuracy of full wave meter
    5. Can simultaneously test two channel pulses whose pulse constant
    6. Wiring identification is available when no load.
    7. Electric energy accumulation function can measure the electric energy meter when it has not pulse output.
    8. Dial test function
    9. Display vector diagram
    10. Can identify wrong wiring (48 types connections)
    11. Instrument can be simulate the scene of variety of wiring and get corresponding the result of wiring and revised parameter in office without access to voltage or current signal situation
    12. Harmonic functions


    Specifications


    Error (100AClamp CT)

    ±0.2%(5A,100A) ±0.5% (other)

    Harmonic

    2nd ~ 51st

    Starting current

    0.05%Ie

    Power Measure Error (Full Wave & Fundamental Wave)

    Active Power (Direct connection)

    ±0.05%

    Active Power (100A ClampCT)

    ±0.2%(5A,100A) ±0.5% (other)

    Reactive Power (Direct connection)

    ±0.1%

    Reactive Power (100A ClampCT)

    ±0.5%(5A,100A) ±1.0% (other)

    Energy Measure Error (Full Wave & Fundamental Wave)

    Active Energy (Direct connection)

    ±0.05% (±0.1%)

    Active Energy (100A ClampCT)

    ±0.2%(5A,100A) ±0.5% (other)

    Reactive Energy (Direct connection)

    ±0.1%

    Reactive Energy (100A ClampCT)

    ±0.5%(5A,100A) ±1.0% (other)

    Error (Harmonic Wave)

    Direct Connection

    kWh,U, I, P, Q, S

    ±0.2%H (H=1+0.01k, k=2~51)

    Clamp CT

    kWh,U, I, P, Q, S

    ±0.5%H (H=1+0.01k, k=2~51)


    5A/100A

    Cycle Output Current for 5A CCT’s Self Calibration

    0.05A,0.1A,0.25A,0.5A,1A,2.5A,5A

    Error of 5ACCT’s Self Calibration

    ±0.1%


    (linear and phase error)

    Clamp CT 500A/1000A

    kWh,U, I, P, Q, S

    ±1.0%H (H=1+0.01k, k=2~51)

    Error - Others

    Ratio Measurement

    ±0.5%

    Voltage Influence

    <±0.01%

    Frequency Influence

    <±0.01%

    Temperature Influence

    <±0.01%/℃

    24h Accuracy Influence

    <±0.01%

    Harmonic Influence

    <±0.01%

    Phase angle

    Range

    - 180°~ 180°

    Error

    <±0.1°

    Frequency

    Range

    45 ~ 65Hz

    Error

    ±0.01Hz

    Pulse output

    Inner High frequency (CH)

    1.8x109 P/kWh

    1.8x109 *(5/Ie)P/kWh

    Low frequency output

    3600P, 36000P,


    360000P/kWh(kvarh, kVAh)

    3600P, 36000P,


    360000P


    *(5/Ie)P/kWh(kvarh, kVAh)

    Pulse ratio

    1:01

    Output level

    +5V (can be adjusted according to request)

    Pulse input

    Input Channel

    2

    Input level

    5 ~ 10V

    Max Pulse Input frequency

    Max. 10kHz

    Display

    Resolution

    7’’TFT Touch Screen

    System

    Windows CE

    Other

    Voltage supply mode

    External power, Tested circuit, Battery

    Working power supply

    AC 55~600V

    Voltage Withstand

    4.0kV (voltage ¤t terminals, power supply & low voltage terminals)

    EFT(Electrical Fast Transient)

    2.0kV

    IP Level

    IP51

    Surge

    2.0kV (common mode), 2.0kV (different mode)

    Power on Stability Time

    < 3mins

    Chargeable battery

    11.1V 3000mAh

    Power Consumption

    <9W

    Operation Temperature

    Temperature -20℃ ~ +55℃, humidity 40% ~ 95%

    Storage Temperature

    Temperature -40℃ ~ +80℃, humidity 40% ~ 95%

    Dimension (mm) (W×H×D)

    Main

    245×150×50

    Carry case

    425×336×196

    Weight (kg)

    Main

    2

    Whole set

    10


    Portable Three Phase Meter Calibrator for Accurate Voltage and Current Measurement

    Portable Three Phase Meter Calibrator for Accurate Voltage and Current Measurement

    *If you want to know more please check our official website:http://www.genymetertestequipment.com/

    Quality Portable Three Phase Meter Calibrator for Accurate Voltage and Current Measurement for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangzhou GENY Electric Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)