Sign In | Join Free | My himfr.com
Home > Portable Reference Standard >

Customized Yc98s1 Energy Meter Calibrator Three Phase For Measuring Needs

Guangzhou GENY Electric Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Customized Yc98s1 Energy Meter Calibrator Three Phase For Measuring Needs from wholesalers
     
    Buy cheap Customized Yc98s1 Energy Meter Calibrator Three Phase For Measuring Needs from wholesalers
    • Buy cheap Customized Yc98s1 Energy Meter Calibrator Three Phase For Measuring Needs from wholesalers

    Customized Yc98s1 Energy Meter Calibrator Three Phase For Measuring Needs

    Ask Lasest Price
    Certification : ISO, CE
    Supply Ability : 300/Year
    Payment Terms : L/C, T/T, D/P
    Brand Name : GENY
    Model Number : YC98S1
    • Product Details
    • Company Profile

    Customized Yc98s1 Energy Meter Calibrator Three Phase For Measuring Needs

    Customized Yc98s1 Portable Three Phase Standard Meter Test Machine for Measuring Needs

    YC98S1 Portable 3 Phase Standard Meter

    The instrument YC98S1 is used to calibrate three phase, single phase, active or reactive energy
    meter who comply with GB/T17215.211 (IEC62052-11), GB/T17215.311 /321/322/323
    (IEC62053-11/21/22/23), and also it can be used as voltage, current and power meter to measure
    AC parameter of three phase power grid.
    This portable three phase standard meter comply to GB/T11150-2001 (IEC60736:2001),
    GB/T4793.2-2008 (IEC61010-1:2001).

    Test functions

    1. Can test one meter or two meters at the same time.

    2. Automatic test sequence using the scanning head for electronic and electromechanical meters

    3. Can synchronously calculate all data and display on the interface include full wave

    4. Can test active and reactive energy accuracy of full wave meter

    5. Can simultaneously test two channel pulses whose pulse constant

    6. Wiring identification is available when no load.

    7. Electric energy accumulation function can measure the electric energy meter when it has not pulse output.

    8. Dial test function

    9. Display vector diagram

    10. Can identify wrong wiring (48 types connections)

    11. Instrument can be simulate the scene of variety of wiring and get corresponding the result of wiring and revised parameter in office without access to voltage or current signal situation

    12. Harmonic functions

    Specifications


    Test Voltage (Full Wave & Fundamental Wave)
    Range0~500V
    Error±0.05% (0.1%)
    Harmonic2nd ~ 51st
    Test Current (Full Wave & Fundamental Wave)
    Range (direct connection)0.025A ~ 12A (Ie=5A)
    Range (100AClamp CT)

    0.5~120A (Ie=100A,usage range=0.01Ie~2.4Ie)

    (Optional: Ie=5A, 500A, 1000A)

    Error (direct connection)±0.05% (0.1%)
    Error (100AClamp CT)±0.2%(5A,100A) ±0.5% (other)
    Harmonic2nd ~ 51st
    Starting current0.05%Ie
    Power Measure Error (Full Wave & Fundamental Wave)
    Active Power (Direct connection)±0.05%
    Active Power (100A ClampCT)±0.2%(5A,100A) ±0.5% (other)
    Reactive Power (Direct connection)±0.1%
    Reactive Power (100A ClampCT)±0.5%(5A,100A) ±1.0% (other)

    Energy Measure Error (Full Wave & Fundamental Wave)
    Active Energy (Direct connection)±0.05% (±0.1%)
    Active Energy (100A ClampCT)±0.2%(5A,100A) ±0.5% (other)
    Reactive Energy (Direct connection)±0.1%
    Reactive Energy (100A ClampCT)±0.5%(5A,100A) ±1.0% (other)
    Error (Harmonic Wave)
    Direct ConnectionkWh,U, I, P, Q, S±0.2%H (H=1+0.01k, k=2~51)

    Clamp CT

    5A/100A

    kWh,U, I, P, Q, S±0.5%H (H=1+0.01k, k=2~51)
    Cycle Output Current for 5A CCT’s Self Calibration0.05A,0.1A,0.25A,0.5A,1A,2.5A,5A

    Error of 5ACCT’s Self Calibration

    (linear and phase error)

    ±0.1%
    Clamp CT 500A/1000AkWh,U, I, P, Q, S±1.0%H (H=1+0.01k, k=2~51)
    Error - Others
    Ratio Measurement±0.5%
    Voltage Influence<±0.01%
    Frequency Influence<±0.01%
    Temperature Influence<±0.01%/℃
    24h Accuracy Influence<±0.01%
    Harmonic Influence<±0.01%
    Phase angle
    Range- 180°~ 180°
    Error<±0.1°
    Frequency
    Range45 ~ 65Hz
    Error±0.01Hz
    Pulse output
    Inner High frequency (CH)Direct connection1.8x109 P/kWh
    Clamp CT1.8x109 *(5/Ie)P/kWh
    Low frequency outputDirect connection

    3600P, 36000P,

    360000P/kWh(kvarh, kVAh)

    Clamp CT

    3600P, 36000P,

    360000P

    *(5/Ie)P/kWh(kvarh, kVAh)


    Pulse ratio1:1
    Output level+5V (can be adjusted according to request)
    Pulse input
    Input Channel2
    Input level5 ~ 10V
    Max Pulse Input frequencyMax. 10kHz
    Display
    Resolution7’’TFT Touch Screen
    SystemWindows CE
    Other
    Voltage supply modeExternal power, Tested circuit, Battery
    Working power supplyAC 55~600V
    Voltage Withstand4.0kV (voltage ¤t terminals, power supply & low voltage terminals)
    EFT(Electrical Fast Transient)2.0kV
    IP LevelIP51
    Surge2.0kV (common mode), 2.0kV (different mode)
    Power on Stability Time< 3mins
    Chargeable battery11.1V 3000mAh
    Power Consumption<9W
    Operation TemperatureTemperature -20℃ ~ +55℃, humidity 40% ~ 95%
    Storage TemperatureTemperature -40℃ ~ +80℃, humidity 40% ~ 95%
    Dimension (mm) (W×H×D)Main245×150×50
    Carry case425×336×196
    Weight (kg)Main2
    Whole set10


    Quality Customized Yc98s1 Energy Meter Calibrator Three Phase For Measuring Needs for sale