Sign In | Join Free | My himfr.com
Home > Portable Meter Test System >

Portable Energy Meter Testing Equipment YC99T Series

    Buy cheap Portable Energy Meter Testing Equipment YC99T Series from wholesalers
     
    Buy cheap Portable Energy Meter Testing Equipment YC99T Series from wholesalers
    • Buy cheap Portable Energy Meter Testing Equipment YC99T Series from wholesalers

    Portable Energy Meter Testing Equipment YC99T Series

    Ask Lasest Price
    Brand Name : GENY
    Model Number : YC99T
    Certification : ISO, CE
    Payment Terms : L/C,T/T,D/P
    Supply Ability : 50/Year
    • Product Details
    • Company Profile

    Portable Energy Meter Testing Equipment YC99T Series

    Portable Energy Meter Testing Equipment YC99T Series


    Product Description



    The product is used in a variety of professional settings, including measurement testing centres of grid companies, measurement departments of power supply companies and power plants, national measurement testing institutions and metrology inspection departments, measurement testing departments of medium-sized enterprises such as railway and petrochemical companies. Additionally, it is utilised by manufacturers of energy meters, encompassing their production, research and development, and testing departments, as well as in academic institutions and associated research bodies.



    Simple Description



    This product is used in a variety of professional settings, including measurement testing centres of grid companies, measurement departments of power supply companies and power plants, national measurement testing institutions and metrology inspection departments, measurement testing departments of medium-sized enterprises such as railway and petrochemical companies. It is also used by manufacturers of energy meters, including their production, research and development, and testing departments, as well as in universities and related research institutions, and specialised laboratories.

    The meters user can calibrate the following meters: single-phase active energy meter, three-phase three-wire active energy meter, three-phase three-wire composite meter, three-phase four-wire active energy meter, three-phase four-wire composite meter, three-phase three-wire sine reactive energy meter, three-phase four-wire sine reactive energy meter, two elements 60° reactive energy meter, two elements 90° reactive energy meter, and three elements 90° reactive energy meter.


    Specifications




    Model No.

    YC99T-3C

    Meter Position / Accuracy

    3 / 0.05

    AC Voltage output

    Range

    57.7V,100V, 220V, 380V 660

    Adjustment Range

    (0-120)%RG (RG is Range)

    Adjust Resolution

    0.01%RG, 0.1%RG, 1%RG, 10%RG

    Stability

    0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)

    Distortion

    0.2% (Non capacitive load)

    Max Output load

    20VA/phase

    Measurement Accuracy

    %0.05%RG(0.05cl), %0.1%RG(0.1cl)

    AC Current output

    Range

    0.05A 0.2A 1A 5A 16.67A 50A

    Adjust Range

    (0-120)%RG (RG is Range)

    Adjust Resolution

    0.01%RG, 0.1%RG, 1%RG, 10%RG

    Stability

    0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)

    Distortion

    0.2% (Non capacitive load)

    Max Output load

    50VA(50A range)

    Measurement Accuracy

    %0.05%RG(0.05cl), %0.1%RG(0.1cl)

    Power output

    Stability

    0.01%/2min(0.05cl), 0.02%/2min(0.1cl)

    Active, Reactive power accuracy

    %0.05%RG

    Phase output

    Output adjusting range

    0 ~ 359.99

    Output adjusting power

    10°,1°,0.1°,0.01°optional

    Resolution

    0.01

    Measurement accuracy

    %0.05

    Power factor output

    Adjusting range

    -1~0~+1

    Measuring resolution

    0.0001

    Measurement accuracy

    %0.0005

    Frequency output

    Adjusting range

    40Hz – 70Hz

    Output adjusting resolution

    1Hz, 0.1Hz, 0.01Hz, 0.001Hz optional

    Resolution

    0.001Hz

    Accuracy

    %0.002Hz

    Harmonic setting

    Harmonic order

    2nd~63rd

    Harmonic amplitude

    0~40%

    Harmonic angle

    0 ~359.00

    Harmonic set error

    2nd ~ 31st : %0.1%, 32nd~63rd: %0.2%

    Energy error measurement

    Active energy basic error limit

    %0.05%RD(voltage30V~660V,current0.02A~60A,PF 0.5)

    Reactive energy basic error limit

    %0.1%RD(voltage30V~660V,current0.02A~60A,PF 0.5)

    Standard crystal

    Frequency accuracy

    %0.5ppm (leave factory@25 )

    Frequency stability

    %0.1ppm,-20 ~+70

    Energy pulse input

    Number of energy pulse input

    3 channels active, 3 channels reactive

    General parameters

    Power supply

    AC220V%15% or 110V%15%

    Frequency

    50Hz~60Hz

    Consumption

    60VA~1000VA

    Environment condition

    20 ~ 30 relative humidity

    Storage environment

    -20 ~50

    Size & Weight

    600mm(L) 400mm(W) 266mm(H), 30kg



    Model No.

    YC99T-5C

    Meter Position / Accuracy

    3 / 0.05cl

    AC Voltage output

    Range

    57.7V,100V, 220V, 380V

    Adjustment Range

    (0-120)%RG (RG is Range)

    Adjust Resolution

    0.01%RG, 0.1%RG, 1%RG, 10%RG

    Stability

    0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)

    Distortion

    0.2% (resistance load)

    Max Output load

    20VA/phase

    Measurement Accuracy

    %0.05%RG(0.05cl), %0.1%RG(0.1cl)

    AC Current output

    Range

    0.05A 0.2A 1A 5A 20A 100A

    Adjust Range

    (0-120)%RG (RG is Range)

    Adjust Resolution

    0.01%RG, 0.1%RG, 1%RG, 10%RG(optional)

    Stability

    0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)

    Distortion

    0.2% (Non capacitive load)

    Max Output load

    100VA(100A range)

    Measurement Accuracy

    %0.05%RG(0.05cl), %0.1%RG(0.1cl)

    Power output

    Stability

    0.01%/2min(0.05cl), 0.02%/2min(0.1cl)

    Active, Reactive power accuracy

    %0.05%RG

    Phase output

    Output adjusting range

    0 ~ 359.99

    Output adjusting power

    10°,1°,0.1°,0.01°optional

    Resolution

    0.01

    Measurement accuracy

    %0.05

    Power factor output

    Adjusting range

    -1~0~+1

    Measuring resolution

    0.0001

    Measurement accuracy

    %0.0005

    Frequency output

    Adjusting range

    45Hz – 70Hz

    Output adjusting resolution

    1Hz, 0.1Hz, 0.01Hz, 0.001Hz

    Resolution

    0.001Hz

    Accuracy

    %0.002Hz

    Harmonic setting

    Harmonic order

    2nd~63rd

    Harmonic amplitude

    0~40%

    Harmonic angle

    0 ~359.99

    Harmonic set error

    2nd ~ 31st : %0.1%, 32nd~63rd: %0.2%

    Energy error measurement

    Active energy basic error limit

    %0.05%RD(voltage30V~380V,current0.02A~120A,PF 0.5)

    Reactive energy basic error limit

    %0.1%RD(voltage30V~380V,current0.02A~120A,PF 0.5)

    Standard crystal

    Frequency accuracy

    %0.5ppm (leave factory@25 )

    Frequency stability

    %0.1ppm,-20 ~+70

    Energy pulse input

    Number of energy pulse input

    3 channels active, 3 channels reactive

    General parameters

    Power supply

    AC220V%15% or 110V%15%

    Frequency

    50Hz~60Hz

    Consumption

    60VA~1000VA

    Environment condition

    20 ~ 30 relative humidity

    Storage environment

    -20 ~50

    Size & Weight

    600mm(L) 400mm(W) 266mm(H), 48kg


    Portable Energy Meter Testing Equipment YC99T Series


    Portable Energy Meter Testing Equipment YC99T Series

    Quality Portable Energy Meter Testing Equipment YC99T Series for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangzhou GENY Electric Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)