    • Buy cheap Portable Reference Standard YC-98S1 High Accuracy Test Equipment For Industrial Power Measurement from wholesalers

    Portable Reference Standard YC-98S1 High Accuracy Test Equipment For Industrial Power Measurement

    Ask Lasest Price
    Brand Name : GENY
    Model Number : YC89S1
    Certification : ISO, CE
    Payment Terms : L/C, T/T, D/P
    Supply Ability : 300/Year
    • Product Details
    • Company Profile

    Portable Reference Standard YC-98S1 High Accuracy Test Equipment For Industrial Power Measurement

    Portable Reference Standard YC-98S1 High Accuracy Test Equipment for Industrial Power Measurement

    Product Parameters

    Application Conditlons and Requirements
    EnvironmentSafety
    Operation TemperatureRelative HumidityAltitudeIP ClassConformity
    -25°C-+45°C40%--95%<2500mIP30CE conform
    TypeYC-98S1
    Test voltage
    Range30V-480V
    Error±0.05%
    Harmonic2nd-51st
    Test current
    Range(direct connection)0.05-10A
    Range(clamp CT)100A
    5A,500A,1000A,2000A
    (option)
    Error(direct connection)±0.05%
    Error(clamp CT)±0.2%(5A,100A)
    ±0.5%(other)
    Harmonic2nd-51st
    Power measure error
    Active power(direct connection)±0.05%
    Active power(clamp CT)±0.2%(5A,100A) ±0.5%(other)
    Reactive power(direct)±0.1%
    Reactive power(clamp CT)±0.2%(5A,100A)
    ±0.5%(other)
    Energy measure error
    Active energy(direct)±0.05%
    Active energy(clamp CT)±0.2%(5A,100A)
    ±0.5%(other)
    Reactive energy(direct)±0.1%
    Reactive energy(clamp CT)±0.2%(5A,100A)
    ±0.5%(other)
    Phase angle
    Range0°-360°
    Error±0.05°
    Frequency
    Range45Hz-65Hz
    Pulse output
    High frequency output(CH)--
    Low frequency3600imp/kWh
    Pulse ratioPulse ratio1:01
    Output level5V
    Pulse input
    Input channel2
    Input level5-10V
    Input frequencyMax.100Hz
    Display
    Resolution7"TFT color
    Function
    Vector diagram
    Waveform
    Energy accumulation
    CT ratio test
    Local parameter input
    Wiring emulation
    Self-calibration
    Recorder check
    Data storage
    Data storage qty5000
    External extend
    Screen printing
    Communication portUSB/RS232
    Communication with
    Upload data
    External mini printer
    External keyboard
    Other
    Voltage Supply wayExternal power
    test lead power
    Voltage Supply55-480V,50/60Hz
    Dimensions(WxHxD)245x168x67
    Weight(kg)1.5kg

    Features and Functions

    • On-site error measurement of electricity meters 1P2W, 1P3W, 3P3W, 3P4W
    • High accuracy class 0.05 in direct mode
    • Can simultaneously test two channel pulses whose pulse constant, modes and pulse quantities can be different
    • Direct measurement up to 12A/480V
    • Current measurement with AC clamps from 5A to 2000A
    • Harmonics up to 51st
    • Burden measurement of CT & PT
    • Verification of meter wiring connections
    • 7 inch TFT color screen
    • Supply via external power, test lead or battery (optional)

    Our Advantages

    1. We have been engaged in the Electric Energy Meter measurement field for over twenty years as an all-time technological leader and creator of new technology in the Electric Energy Meter calibrator field. We have an excellent R&D team that has devoted to the technical development of Electric Energy Meter test instruments for a long time, we can satisfy different requirements of all kinds of customers.
    2. All of our staff have received specialized training and acquired good professional quality and skills. The company adopts ISO9001 management and we have passed the authentication of ISO9001-2000 in 2002 and all staff has taken TQM training. Yangcheng has now realized ISO9001 control of R&D production, marketing & sales, and service completely to guarantee product quality.
    3. We have a consummate marketing network and we offer a competitive price.
    4. Our well-trained service team is able to provide maintenance, training, scheme design, and software update services to each customer for the first time.

    Portable Reference Standard YC-98S1 High Accuracy Test Equipment For Industrial Power Measurement